The browser-facing WebSocket accepted requests from any local page, so a
page could launch or terminate apps and inject messages into any session.
Every connection now completes the upgrade and sends HELLO within five
seconds. The system role authenticates with a token appd writes to
$XDG_RUNTIME_DIR/weft/appd.systoken (mode 0600) and may manage sessions,
but never sees or sends application messages. The app role authenticates
with a per-session bridge token passed to weft-app-shell in
WEFT_BRIDGE_TOKEN and exchanges APP_MESSAGE envelopes with its own
session only; it is disconnected when that session stops.
weft-servo-shell hands the system endpoint only to the system UI
document and denies navigation away from it. weft-app-shell installs the
bridge only in top-level documents inside the application's UI
directory and denies navigation outside it. The launcher renders package
names as text.
tests/frame/check_counter.py drives the Counter demo end to end through
the compositor, appd, the Wasm runtime and the app shell.
weft-appd marked a session Running and broadcast APP_READY as soon as the
runtime printed READY, then started weft-app-shell with its output
discarded and never watched it. A session with no UI, a UI host that
failed to start, or one that crashed was still reported running. Early
failure paths skipped parts of the cleanup: the image mount was not
unmounted, the compositor association was not released, and the abort
sender leaked on spawn failure. Readiness was any stdout line equal to
READY, which a Wasm guest (inherited stdout) or a page (window.alert
writes to the app shell's stdout) could print.
Now a session becomes Running only after the runtime and then the app
shell report readiness, each within 30 s; WEFT_APP_SHELL_BIN is required
and checked before anything starts. After that, the runtime exiting, the
app shell exiting or a terminate request ends the session. Every exit
path goes through one teardown that kills both children, releases the
compositor association, unmounts the image, stops the file portal and
broadcasts Stopped.
Readiness uses a per-session random token passed to both children in
WEFT_READY_TOKEN. weft-runtime and weft-app-shell print READY <token>,
and appd accepts only a line ending with it; guests receive only the
variables the runtime names and pages cannot read the host environment.
Child output is read in bounded, lossily decoded lines, so invalid UTF-8
or long lines no longer stop the readers. Compositor notifications use
try_send so a disconnected compositor cannot stall teardown, and all
children are killed if the supervisor is dropped.
The IPC relay is not yet owned by the session, and children are killed
without a graceful period.
Validation:
- cargo test -p weft-appd (43 passed); new tests cover: not ready until
the app shell is ready, runtime exit before that, no app shell
configured (runtime never starts), app shell exit ending a running
session with the runtime process gone, and READY lines without the
token; they fail against the previous supervisor
- end to end with weft-compositor (nested), weft-appd, weft-runtime
(wasmtime-runtime) and weft-app-shell: the Counter demo reaches
APP_READY and is on screen; a page that prints a READY line through
alert and never loads is stopped after 30 s without APP_READY;
terminate leaves no child processes
- clippy -D warnings and fmt --check for weft-appd and weft-runtime
- flake.nix, infra/nixos/: NixOS VM with Mesa, virtio-gpu, Wayland,
systemd user services for compositor and session supervisor
- infra/vm/: QEMU build and run scripts
- .github/workflows/ci.yml: add Linux job to type-check weft-servo-shell
and weft-app-shell with --features servo-embed
- docs/architecture.md, docs/security.md, docs/building.md: replace
stale pre-implementation design documents
- README.md: rewrite to reflect current codebase
- crates/weft-servo-shell/SERVO_PIN.md: update implementation status and add
SpiderMonkey process boundary statement